Input |
Input Voltage | 12 -30 Vdc |
| Input power rating | 90 W | |
| Charging current | 2 A | |
| Output | Output Voltage | 24Vdc +/-10% |
| Max. output current | 2.5 A | |
| Battery | Battery Capacity | 14.4 VDC, 1750 mAH |
| Cycle life | 300 times of charge circle (Above 60% capacity compared to the initial state) | |
| Protection | Short-circuit protection | Yes |
| Over discharge protection | IPS shuts down when 5% of battery capacity (Default) | |
| Certification | EMC | CE, FCC, BSMI |
| Safety | UL, CB, BSMI | |
| Dimensions | 151.8 x 125 x 37.2 mm (5.98" x 4.92" x 1.46") | |
|
Environment |
Operating Temperature | 0 ~ 50°C (Din rail mounting)
0-45°C (VESA mounting, secured with PPC) |
| Storage Temperature | -20 ~ 50°C | |
| Relative Humidity | 10 ~ 95% @ 40°C (non-condensing) | |
| Shock Operating | 10 G peak acceleration (11 ms duration), follow IEC 60068-2-27 | |
| Vibration | Operating Random Vibration Test 5 ~ 500Hz, 1Grms, follow IEC 60068-2-64 | |
| I/O Connectors | PS_ON to shut down PC
RS-232 for monitoring and setting IPS |
Ordering Information
| Part No. | Description |
| PPC-IPS-AU | 12-30 VDC input/24 VDC output, Uninterruptible Power Supply Module |
| 98R3612001E | PPC-IPS power cable 1 m |
| 98R3612002E | PPC-IPS control cable 1 m |
| 1760001866-01 | PPC-IPS battery pack (spare part) |
Note: The PPC-IPS-AU is equipped with a battery pack / 300 mm power cable / 300 mm control cable. If a longer cable is needed, the customer can order the 1 meter 98R3612001E and 98R3612002E cables.
The PPC-IPS-AU only currently supports the PPC-300 series, please contact Advantech first for operating with other PC systems.